Reading the screen
Surfaces: Work and Glance
plottypus has two surfaces and nothing else. v cycles between them; the layout setting (auto, work, glance) picks the one it starts on.
Work#
The default in any window of at least 60 columns by 16 rows. The machine sits on the left in a grid of panels, the process table on the right.
╭ cpu 3% 42° … ───── 10% [↗]╮╭ gpu 3% 38° … ───── 10% [↗]╮ ╭ proc 22 ──────────────────────────────[↗]╮
│ ││ │ │ / search / to filter │
│ ⣿││ ⢀│ │ pid name user cpu%↓ │
╰─−2m─────────────────────now─╯╰─−2m─────────────────────now─╯ │▌ 412 WindowServer _windows… 9.8│
╭ mem 12.7G/24.0G … ──────[↗]╮╭ heat peak 45° … ────────[↗]╮ │ 2240 Safari Web Content dev 7.2│- The process table takes 55% of the width by default. Drag the gutter to change it (35% to 72%); the new width is saved as
proc.ratio. - Panel order is fixed: cpu, gpu, mem, net, disk, heat, power, then the process table.
tabandshift-tabwalk it. enteroreon a focused panel expands it to fill the screen, with larger graphs, per-core bars and the related panels as small graphs on the side.tabinside an expanded panel hops to a related one (cpu ↔ gpu ↔ heat, net ↔ disk, mem ↔ processes).escgoes home.- The power panel takes its own row when there is room.
Glance#
For a small window you leave open in a corner. Glance is chosen automatically below 60×16, or with v, --surface glance or layout = glance.
The cpu graph takes two fifths of the height. The other panels form an even grid of strips under it, and the power panel becomes the last strip. There is no process table. The cpu title adds each cluster’s clock, for example S 1.3G · P 1.0G.
╭ cpu 3% S 1.3G · P 1.0G 1.3W 44° ──────────────────────────── 10% [↗]╮
│ ⣀⣀⣀⣀⣀⣀│
│ ⣿⣿⣿⣿⣿⣿│
╰─−2m──────────────────┴──────────────────┴─────────────────┴───────────now─╯
╭ gpu 2% 466MHz 0.4W 38° ─── 10% [↗]╮╭ mem 12.8G/24.0G swap 820M ─[↗]╮auto#
With layout = auto (the default), plottypus follows the window: Work at 60×16 and above, Glance below. Resizing the window switches it live. v overrides it for the rest of the session without touching your config.
Zen mode#
Z hides the footer and the scale labels on either surface and leaves only the graphs. It is saved as zen = true. The ricer preset (5) is Glance with zen on and every panel showing.
Time on the graphs#
Every compact graph on a surface shows the same two-minute window, so panels of any width line up in time. The bottom border carries the scale: −2m ┴ … ┴ now. z steps the zoom through 5 minutes, 15 minutes, 1 minute and back to the live two minutes. Expanded panels keep their own zoom, and open at 5 minutes.
Auto scales print their ceiling in the top border (10%, 500KB/s, 35–50°), computed over the time on screen, so the label matches what is drawn. A fixed 0–100% scale has no label.